CHROMATOGRAPHIC COLUMN AGILENT TECHNOLOGIES S/M CHROMATOGRAPHIC COLUMN OF 60 METERS BY 0.25MM DIAMETER AND 140 MICRONS OF PHASE THICKNESS STATIONARY OF DB-624 ULTRA INERT. USE: SEPARATE THE COMPONENTS OF A SAMPLE BY THEIR MIGRATION DB-624 UI 60M 0.25MM 1.40U DIFFERENTIAL WHEN CROSSING THE COLUMN DRIVEN BY A MOBILE PHASE. FUNCTION: CHROMATOGRAPH ACCESSORY
CHROMATOGRAPHIC COLUMN AGILENT TECHNOLOGIES S/M CHROMATOGRAPHIC COLUMN OF 60 METERS BY 0.25MM DIAMETER AND 140 MICRONS OF PHASE THICKNESS STATIONARY OF DB-624 ULTRA INERT. USE: SEPARATE THE COMPONENTS OF A SAMPLE BY THEIR MIGRATION DB-624 UI 60M 0.25MM 1.40U DIFFERENTIAL WHEN CROSSING THE COLUMN DRIVEN BY A MOBILE PHASE. FUNCTION: CHROMATOGRAPH ACCESSORY
CAPILLARY COLUMN AGILENT TECHNOLOGIES S/M OF 30 METERS OF LENGTH X 0.25 MM OF INTERNAL DIAMETER AND 0.25 MICRONS OF THICKNESS OF THE STATIONARY PHASE FUNCTION AND USE: REPLACEMENT OF GAS CHROMATOGRAPHY PROVIDES THE MEANS FOR THE SEPARATION OF THE 122-5532UI DB-5MS ULTRA INERT 30M 0.25MM 0.25UM COMPONENTS OF A SAMPLE BY THEIR DIFFERENTIAL MIGRATION WHEN PASSING THROUGH IT DRIVEN BY A MOBILE PHASE
CAPILLARY COLUMN AGILENT TECHNOLOGIES S/M OF 30 METERS OF LENGTH X 0.25 MM OF INTERNAL DIAMETER AND 0.25 MICRONS OF THICKNESS OF THE STATIONARY PHASE FUNCTION AND USE: REPLACEMENT OF GAS CHROMATOGRAPHY PROVIDES THE MEANS FOR THE SEPARATION OF THE 122-5532UI DB-5MS ULTRA INERT 30M 0.25MM 0.25UM COMPONENTS OF A SAMPLE BY THEIR DIFFERENTIAL MIGRATION WHEN PASSING THROUGH IT DRIVEN BY A MOBILE PHASE
01-March-2023
9027909000
AGILENT TECHNOLOGIES S/M CAPILLARY COLUMN USE: GAS CHROMATOGRAPHY SYSTEM ACCESSORY FUNCTION: WHEN PASSING THROUGH IT BY THE MOBILE PHASE ITS COMPONENTS ARE SEPARATED BY HAVING A CAPILLARY COLUMN OF 15 METERS LENGTH X 0.25MM DIAMETER AND 0.10 MICRONS THICKNESS OF THE 122-5711-INT
AGILENT TECHNOLOGIES S/M CAPILLARY COLUMN USE: GAS CHROMATOGRAPHY SYSTEM ACCESSORY FUNCTION: WHEN PASSING THROUGH IT BY THE MOBILE PHASE ITS COMPONENTS ARE SEPARATED BY HAVING A CAPILLARY COLUMN OF 15 METERS LENGTH X 0.25MM DIAMETER AND 0.10 MICRONS THICKNESS OF THE 122-5711-INT
12-January-2024
9027909000
CHROMATOGRAPHIC COLUMN OF 4.6X250MM. AGILENT TECHNOLOGIES S/M FILLED WITH THE STATIONARY PHASE POROSHELL 120 HPH-C18 OF 4 MICRONS PARTICLE SIZE USE: HPLC ACCESSORY / FUNCTION: SEPARATE THE COMPONENTS OF A SAMPLE 690970-702 POROSHELL 120 HPH-C18 4.6X250MM 4UM DUE TO ITS DIFFERENTIAL MIGRATION WHEN CROSSING THE COLUMN DRIVEN BY THE MOBILE PHASE
CHROMATOGRAPHIC COLUMN OF 4.6X250MM. AGILENT TECHNOLOGIES S/M FILLED WITH THE STATIONARY PHASE POROSHELL 120 HPH-C18 OF 4 MICRONS PARTICLE SIZE USE: HPLC ACCESSORY / FUNCTION: SEPARATE THE COMPONENTS OF A SAMPLE 690970-702 POROSHELL 120 HPH-C18 4.6X250MM 4UM DUE TO ITS DIFFERENTIAL MIGRATION WHEN CROSSING THE COLUMN DRIVEN BY THE MOBILE PHASE
12-January-2024
9027909000
CHROMATOGRAPHIC COLUMN AGILENT TECHNOLOGIES S/M HIGH SPEED AND RESOLUTION (RRHD) OF 150 MM LENGTH X 3 MM DIAMETER AND 1.8 U PARTICLES USE: HPLC ACCESSORY FUNCTION: SEPARATE THE COMPONENTS BY THEIR 959759-302 ECLIPSE PLUS C18 RRHD 3.0X150MM 1.8UM DIFFERENTIAL MIGRATION WHEN CROSSING THE STATIONARY PHASE ECLIPE PLUS C18 DRIVEN BY THE MOBILE PHASE
CHROMATOGRAPHIC COLUMN AGILENT TECHNOLOGIES S/M HIGH SPEED AND RESOLUTION (RRHD) OF 150 MM LENGTH X 3 MM DIAMETER AND 1.8 U PARTICLES USE: HPLC ACCESSORY FUNCTION: SEPARATE THE COMPONENTS BY THEIR 959759-302 ECLIPSE PLUS C18 RRHD 3.0X150MM 1.8UM DIFFERENTIAL MIGRATION WHEN CROSSING THE STATIONARY PHASE ECLIPE PLUS C18 DRIVEN BY THE MOBILE PHASE