HS-Code
Products
9016001000
1.GOODS IMPORTED IN CONNECTION WITH OR IN SUPPORT OF THE NATO PROJECT SPS G5373 MODERNIZATION OF THE MANUAL GAMMA DETECTOR BASED ON HPXE GAS IMPLEMENTED UNDER THE NATO PROGRAM SCIENCE FOR PEACE AND SECURITY SALE PROHIBITED: SCALES : ART.611-4974 BALANCE EXPLORER EX24001 / M 24KGX0.1G EU / PRECISION SCALES EXPLORER EX24001 / M 24KGX0.1G EU -1PC. MANUFACTURER: OHAUS CORPORATION; BRAND: EXPLORER.
8504409000
1.GOODS IMPORTED IN CONNECTION WITH OR IN SUPPORT OF THE NATO PROJECT SPS G5373 MODERNIZATION OF THE MANUAL GAMMA DETECTOR BASED ON HPXE GAS IMPLEMENTED UNDER THE NATO PROGRAM SCIENCE FOR PEACE AND SECURITY SALE IS PROHIBITED: ART.MPD20N10 / 24 POWER SUPPLY MPD SERIES MAXIMUM OUTPUT VOLTAGE 20 KV NEGATIVE POLARITY OF OUTPUT VOLTAGE POWER 10 W MAXIMUM SET VOLTAGE 24 W - 1 PIECE SERIAL NUMBER: 134255044.MANUFACTURER: SPELLMAN HIGH VOLTAGE ELEC LTD.TRADE BRAND: SPELLMAN;
6914900000
1.GOODS IMPORTED IN CONNECTION WITH OR IN SUPPORT OF THE NATO PROJECT SPS G5373 MODERNIZATION OF THE MANUAL GAMMA DETECTOR BASED ON HPXE GAS IMPLEMENTED UNDER THE NATO PROGRAM SCIENCE FOR PEACE AND SECURITY SALE PROHIBITED: MACOR ROD 3 DIA.X12 LONG / MACHOR GLASS-CERAMIC IN THE FORM OF A ROD DIAMETER 3 INCHES LENGTH 12 INCHES. -1PC .; MACOR ROD 3 DIA.X6 LONG / GLASS-CERAMIC MACHINABLE MACOR IN THE FORM OF A ROD DIAMETER 3 INCHES LENGTH 6 INCHES -1PC .; MACOR ROD 2 DIA.X6 LONG / GLASS-CERAMICS MACHINABLE MACOR IN THE FORM OF A ROD DIAMETER 2 INCHES LENGTH 6 INCHES -1PC .; MACOR ROD 1-18 DIA.X3 LONG / GLASS CERAMICS MACHINABLE MACOR IN THE FORM OF A ROD DIAMETER 1-18 INCHES LENGTH 3 INCHES -1PC .; MACOR ROD 7/16 DIA.X6 LONG / MACHINED GLASS CERAMICS MACOR IN THE FORM OF A ROD DIAMETER 7/16 INCHES LENGTH 6 INCHES -1PCS .; MANUFACTURER: CORNING INC .; BRAND: MACOR;
HS-Code
Products
9022290000
1.SCINTILLATION DETECTOR LB6752-11 / SCINTILLATION DETECTORS LB6752-11 - 6 PCS. ARTICLE 48456-11.STSYNTYLYATSIYNYY DETECTOR LB6752-11 WITH WATER COOLING SHROUDS POLYMER SCINTILLATORS 150H100H50 MM-PROTECTED CABLE ENTRY PLUG MOUNTING FLANGE 180H210 POLYMER MM.VELYKYY SCINTILLATOR HYPERSENSITIVITY AND TOCHNOSTI.VSTANOVLYUYETSYA IN THE MOLD OF CONTINUOUS CASTING OF STEEL IS USED TO MEASURE THE LEVEL OF WATER COOLING KRYSTALIZATORA.PERETVORYUYE GAMMA-RAY SOURCE IN ELECTRICAL IMPULSES. THERE SCINTILLATION COUNTER AND INTENDED FOR USE WITH PROCESSORS TO MEASURE THE INTENSITY OF RADIATION IN THE RADIOMETRY PROCESS VYMIRYUVANNYA.NE CONTAINS IN ITS COMPOSITION MATERIALIV.DLYA USE OF RADIOACTIVE STEEL INDUSTRY. FOR OWN PRODUCTION NEEDS OF AMKR PJSC.
9022290000
1.STSYNTYLYATSIYNYY DETECTOR LB6739-01 / SCINTILLATION DETECTOR LB6739-01 ARTICLE / ARTICLE 48452-01 - 6 PCS. SCINTILLATION DETECTORS LB6739-01 STAINLESS STEEL CRYSTALS CSL 40/50 MM-PROTECTED PLUG-IN VVID.VSTANOVLYUYETSYA CABLE CRYSTALLIZER OF CONTINUOUS CASTING OF STEEL SERVES TO CONTROL THE LEVEL OF CASTING STALI.PERETVORYUYE GAMMA-RAY SOURCE IN ELECTRICAL IMPULSES. THERE SCINTILLATION COUNTER AND INTENDED FOR USE WITH PROCESSORS TO MEASURE THE INTENSITY OF RADIATION IN THE RADIOMETRY PROCESS VYMIRYUVAN.NE CONTAINS RADIOACTIVE SOURCES MATERIALIV.DLYA USE METAL INDUSTRY. FOR OWN PRODUCTION NEEDS OF PJSC AMKR.
9022290000
1.SCINTILLATION DETECTOR LB6739-01 / SCINTILLATION DETECTORS LB6739-01 - 6 PCS. ARTICLE 48452-01.STSYNTYLYATSIYNYY DETECTOR LB6739-01 WITH WATER COOLING SHROUDS POLYMER SCINTILLATORS 150H100H50 MM-PROTECTED CABLE ENTRY PLUG MOUNTING FLANGE 180H210 POLYMER MM.VELYKYY SCINTILLATOR HYPERSENSITIVITY AND TOCHNOSTI.VSTANOVLYUYETSYA IN THE MOLD OF CONTINUOUS CASTING OF STEEL IS USED TO MEASURE THE LEVEL OF WATER COOLING KRYSTALIZATORA.PERETVORYUYE GAMMA-RAY SOURCE IN ELECTRICAL IMPULSES. THERE SCINTILLATION COUNTER AND INTENDED FOR USE WITH PROCESSORS TO MEASURE THE INTENSITY OF RADIATION IN THE RADIOMETRY PROCESS VYMIRYUVANNYA.NE CONTAINS IN ITS COMPOSITION MATERIALIV.DLYA USE OF RADIOACTIVE STEEL INDUSTRY. FOR OWN PRODUCTION NEEDS OF AMKR PJSC.
HS-Code
Products
9030100000
1. THE EQUIPMENT FOR DETECTION OF GAMMA RADIATIONS: THE SCINTILLATION DETECTOR LB6752-11 WITH A CASING OF WATER COOLING THE POLYMERIC SCINTILLATOR 150KH100KH50MM THE PROTECTED PLUG SOCKET OF A CABLE INPUT A MOUNTING FLANGE 180KH210MMKOD 48456-11-7 PIECES; IT IS A PART OF INSTALLATION OF SYSTEM. WITHOUT A RADIOACTIVE SOURCE) .THE PRINCIPLE OF OPERATIONDETECTOR: GAMMA RADIATION COMING TO THE DETECTOR CAUSES IN THE CRYSTALMICROFLASHES OF LIGHT INVISIBLE TO THE NAKED EYE THE PHOTOSENSITIVE CATHODEPHOTO CONVERTER CONVERTS FLASHES INTO AN ELECTRON THE ELECTRONIC UNIT FOLLOWING THECEDUCTOR CONVERTS SIGNALS TO THE EMITTER. SCINTILLATION COUNTERS ARE USED. THE DETECTOR CONSISTS OF THE FOLLOWING BLOCKS: THALLIUM-ACTIVATED SODIUM IODIDE CRYSTAL; PHOTOMULTIPLIER; ELECTRIC UNIT. USED IN METALLURGICAL PRODUCTION FOR OWN NEEDS.
9030100000
1. EQUIPMENT FOR DETECTION OF GAMMA RADIATION: SCINTILLATION DETECTOR LB6752-11 WITH WATER-COOLED CASING POLYMER SCINTILLATOR 150X100X50MM PROTECTED PLUG CONNECTOR CABLE ENTRY MOUNTING FLANGE 180X210MM-4PCS; CODE 48456-11 THE PRINCIPLE OF OPERATION OF THE DETECTOR: GAMMA RADIATION COMING TO THE DETECTOR CAUSES IN THE CRYSTAL MICROBLASHES OF LIGHT INVISIBLE TO THE NAKED EYE PHOTOSENSITIVE CATHODE PHOTOMULTIPLIER CONVERTS FLASHES IN THE ELECTRON THE ELECTRONIC UNIT IS FOLLOWED BY THE RADIATION DETECTOR USES SCINTILLATION COUNTERS. THE DETECTOR CONSISTS OF THE FOLLOWING UNITS: THALLIUM-ACTIVATED SODIUM IODIDANATE CRYSTAL; PHOTOMULTIPLIER; ELECTRIC UNIT. IT IS USED IN METALLURGICAL PRODUCTION FOR OWN NEEDS.
9030100000
1. EQUIPMENT FOR DETECTION OF GAMMA RADIATION: LB6752-11 SCINTILLATION DETECTOR WITH WATER-COOLED CASING POLYMER SCINTILLATOR 150X100X50MM PROTECTED PLUG CONNECTOR CABLE ENTRY MOUNTING FLANGE 180X210MM-8PCS CODE 48456-11 (WITHOUT A RADIOACTIVE SOURCE). THE PRINCIPLE OF OPERATION OF THE DETECTOR: GAMMA RADIATION COMING TO THE DETECTOR CAUSES IN THE CRYSTAL MICROBLASHES OF LIGHT INVISIBLE TO THE NAKED EYE PHOTOSENSITIVE CATHODE PHOTOMULTIPLIER CONVERTS FLASHES IN THE ELECTRON THE ELECTRONIC UNIT FOLLOWING THE DIODE CONVERTS THE MULTIPLIER SIGNALS INTO ELECTRIC. THE RADIATION DETECTOR USES SCINTILLATION COUNTERS. THE DETECTOR CONSISTS OF THE FOLLOWING BLOCKS: THALLIUM-ACTIVATED SODIUM IODIDANATE CRYSTAL; PHOTOMULTIPLIER; ELECTRIC UNIT. USED IN METALLURGICAL PRODUCTION FOR OWN NEEDS.
HS-Code
Products
9030100000
1. GONIOMETER DETECTOR DETECTOR FLOW PROP GONIO 86XXART.S701090TFLOW-PROPORTIONAL GONIOMETER DETECTOR IS A HOLLOW CHAMBER MADE OF LIGHT ALLOY WITH A TAUT THREAD-CONTACT ON THE INSULATORS AND A WINDOW MADE OF MYLAR (POLYETHERTERIPHTALATE METALLOID) THICKNESS. IT IS INTENDED FOR REGISTRATION OF GAMMA QUANTA OF SECONDARY X-RAYS BY CONVERSION OF X-RAYS INTO AN ELECTRIC SIGNAL WHICH IS TRANSFERRED TO A REGISTRATION BOARD. IT IS APPLIED ONLY TO DEVICES OF THIS TYPE (X-RAY SPECTROMETERS). TRADE MARK: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFIC
9030100000
1. DETECTOR THERMO FISHER DETECTOR FLOW PROP GONIO 86XXART.S701090TFLOW-PROPORTIONAL DETECTOR GONIOMETER IS AN EMPTY CHAMBER OF LIGHT ALLOY WITH A STRETCHED THREAD-CONTACT ON THE INSULATORS AND A WINDOW MADE OF MYLAR (POLYETHERTERIFTALATE METALLOID 1 THICK). DESIGNED TO RECORD GAMMA RAYS OF SECONDARY X-RAYS BY CONVERTING X-RAYS INTO AN ELECTRICAL SIGNAL TRANSMITTED TO THE REGISTRATION BOARD. USED ONLY FOR DEVICES OF THIS TYPE (X-RAY SPECTROMETERS). TRADEMARK: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFIC
9030100000
1. DETECTOR THERMO FISHER DETECTOR FLOW PROP GONIO 86XXART.S701090TFLOW-PROPORTIONAL DETECTOR GONIOMETER IS A HOLLOW CHAMBER OF LIGHT ALLOY WITH A TAUT THREAD-CONTACT ON THE INSULATORS AND A WINDOW MADE OF MYLAR (POLYETHERTERIFTALATE METALLOID 1 THICK). IT IS INTENDED FOR REGISTRATION OF GAMMA QUANTA OF SECONDARY X-RAY RADIATION BY CONVERSION OF X-RAY RADIATION INTO AN ELECTRIC SIGNAL WHICH IS TRANSFERRED TO A REGISTRATION BOARD. IT IS APPLIED ONLY TO DEVICES OF THIS TYPE (X-RAY SPECTROMETERS). TRADE MARK: THERMO FISHER MANUFACTURER: THERMO FISHER SCIENTIFIC
HS-Code
Products
9030100000
DEVICES FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION COAXIAL GAMMA RADIATION DETECTION UNIT SPECTROMETRIC GCD 35180 BASED ON A CRYSTAL OF PARTICULARLY PURE GERMANIUM OCG IN A DETECTOR P TYPE AND DEWAR VESSEL OF 25 L IN A VERTICAL CRYOSTAT WITH DOCUMENTATION 1PCS WITH A RANGE OF 2828 18 ENERGIES OF THE MEASURED GAMMA RADIATION 40 100000 KEV REGISTRATION EFFICIENCY FOR ENERGY 1 33 MEV 23 ENERGY RESOLUTION FOR ENERGY 122 KEV 872 EV ENERGY RESOLUTION FOR ENERGY 1332 KEV 1708 EV PEAK PEAK RATIO 64 1 OPTIMUM VOLTAGE 2700 V VESSEL CAPACITY FOR DEWAR 22 IN AMPLITUDE-PROPORTIONAL ELECTRICAL SIGNALS FOR FURTHER PROCESSING IN A SPECTROMETRIC DEVICE OR OTHER NUCLEAR PHYSICAL EQUIPMENT DOES NOT CONTAIN EXPLOSIVE SUBSTANCES AND SOURCES OF IONIZING RADIATION IS NOT A PRODUCT OF MILITARY OR DOUBLE RECOGNITION TRADEMARK BSI MANUFACTURER BALTIC SCIENTIFIC INSTRUMENTS COUNTRY OF MANUFACTURE LV
9030100000
DEVICES FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION COAXIAL GAMMA RADIATION DETECTION UNIT SPECTROMETRIC GCD 80210 BASED ON A CRYSTAL OF PARTICULARLY PURE GERMANIUM OCG IN A P-TYPE DETECTOR WITH A DEWAR VESSEL OF 25 L IN A VERTICAL CRYOSTAT WITH DOCUMENTATION 1PCS WITH A RANGE OF 2829 18 MEASURED GAMMA RADIATION 40 100000 KEV RECORDING EFFICIENCY FOR ENERGY 1 33 MEV 24 1 ENERGY RESOLUTION FOR ENERGY 122KEV 1332EV ENERGY RESOLUTION FOR ENERGY 758KEV 1658EV PEAK PEAK RATIO 71 1 OPTIMUM VOLTAGE 2500V VESSEL DEWAR CAPACITY FOR COOLING SYSTEM 25 COOLING IN AMPLITUDE-PROPORTIONAL ELECTRICAL SIGNALS FOR FURTHER PROCESSING IN A SPECTROMETRIC DEVICE OR OTHER NUCLEAR PHYSICAL EQUIPMENT DOES NOT CONTAIN EXPLOSIVE SUBSTANCES AND SOURCES OF IONIZING RADIATION IS NOT A PRODUCT OF MILITARY OR DOUBLE RECOGNITION TRADEMARK BSI MANUFACTURER BALTIC SCIENTIFIC INSTRUMENTS COUNTRY OF MANUFACTURE LV
9030908500
COMPONENTS OF THE GAMMA RADIATION SPECTROMETER INTENDED FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION ART ??? 527 ANALYZER 2PCS PACKING OF EACH IN A PLASTIC SUITCASE THE MAIN TECHNICAL CHARACTERISTICS OF AMPLIFICATION IN A STEP OF 2 5 10 20 50 TIMES INPUT RANGE OF ANALOG DIGITAL CONVERTER FROM 12V TO 500MV DIGITAL CONVERTER FROM 14 BITS 10MHZ LIMITS OF SETTING TIME OF FORMATION FROM 0 1 TO 25MS OF POWER SUPPLY FROM AN ALTERNATING CURRENT NETWORK 230V 50HZ WITH THE ADAPTER 12VDC LI ION BATTERY WORKING TIME WITH THE DETECTOR MORE THAN 14 HOURS USB RS 232 ETHERNET DATA INTERFACE OVERALL DIMENSIONS 164?111?45?? AT THE ANALYZER MEASURING THE ENERGY OF PHOTONS EMITTING RADIONUCLIDES X-RAY AND GAMMA RADIATION IS AN INTEGRAL PART OF THE SEMICONDUCTOR SPECTROMETER GAMMA RADIATION THE ANALYZER IS USED FOR QUANTITATIVE ANALYSIS OF ENVIRONMENTAL SAMPLES FOR SPECIFIC CONTENT GAMMA-EMITTING RADIONUCLIDES NOT A MILITARY OR DUAL-USE ITEM TRADEMARK BSI MANUFACTURER SIA BALTIC SCIENTIFIC INSTRYMENTS COUNTRY OF MANUFACTURE LV
HS-Code
Products
9030100000
1. EQUIPMENT FOR MEASURING IONIZING RADIATION: SEMICONDUCTOR DETECTOR WITH OCHG COMPLETE WITH DEWAR VESSEL AND CONNECTING CABLES TYPE GEM25P4-70-SMP-S SERIAL NUMBER ? 58-TR24094A - 1 PC. THE DETECTOR IS AN INTEGRAL PART OF THE SCANNING EQUIPMENT NUSCAN WHICH IS USED TO ENSURE OCCUPATIONAL HEALTH AND SAFETY STANDARDS AND IS DESIGNED TO DETERMINE THE ACTIVITY OF GAMMA RADIATION FROM RADIONUCLIDES PRESENT IN THE HUMAN BODY. DEWAR VESSEL BUILT INTO THE DETECTOR PROVIDES COOLING OF THE DETECTOR WITH LIQUID NITROGEN TO THE OPERATING TEMPERATURE.MAIN PARAMETERS: - ENERGY RANGE FROM 50 TO 10000 KEV; - ENERGY RESOLUTION OF 122 KEV 57CO NOT MORE THAN 0.85 KEV- ENERGY RESOLUTION ON 1 33 MEV 60CO NO MORE THAN 1 8 KEV - RELATIVE EFFICIENCY ON 1 33 MEV 60CO N
9030100000
1. EQUIPMENT FOR MEASURING IONIZING RADIATION: SEMICONDUCTOR DETECTOR WITH OCG COMPLETE WITH DEWAR VESSEL AND CONNECTING CABLES TYPE GEM25P4-70-SMP-S SERIAL NUMBER ? 58-TR24094A - 1 PC. THE DETECTOR IS AN INTEGRAL PART OF THE SCANNING EQUIPMENT NUSCAN WHICH IS USED TO ENSURE OCCUPATIONAL HEALTH AND SAFETY STANDARDS IS DESIGNED TO DETERMINE THE ACTIVITY OF GAMMA RADIATION FROM RADIONUCLIDES PRESENT IN THE HUMAN BODY AND THE DETECTOR CONVERTS THE ENERGY OF GAMMA RADIATION QUANTA INTO PROPORTIONAL AMPLITUDE-PROPORTIONAL ELECTRICAL SIGNALS. IN THE SPECTROMETRIC DEVICE.THE DEWAR VESSEL BUILT IN THE DETECTOR PROVIDES COOLING OF THE DETECTOR WITH LIQUID NITROGEN TO WORKING TEMPERATURE.THE MAIN PARAMETERS: - ENERGY RANGE FROM 50 TO 10000 KEV; - ENERGY RESOLUTION ON 122 KEV 57CO NO MORE THAN 0 85 KEV - ENERGY RESOLUTION AT 1.33 MEV 60CO NOT MORE THAN 1.8 KEV - RELATIVE EFFICIENCY AT 1.33 MEV 60CO
9030100000
1. EQUIPMENT FOR MEASURING IONIZING RADIATION: SEMICONDUCTOR DETECTOR WITH OCHG COMPLETE WITH DEWAR VESSEL AND CONNECTING CABLES TYPE GEM25P4-70-SMP-S SERIAL NUMBER ? 58-TR51755V - 1 PC. THE DETECTOR IS AN INTEGRAL PART OF THE NUSCAN SCANNING HUMAN RADIATION SPECTROMETER (SSIC) EQUIPMENT WHICH SERVES TO ENSURE OCCUPATIONAL HYGIENE AND SAFETY STANDARDS. DESIGNED TO DETERMINE THE ACTIVITY OF GAMMA RADIATION COMING FROM RADIONUCLIDES PRESENT IN THE HUMAN BODY. THE DETECTOR CONVERTS THE ENERGY OF GAMMA RADIATION QUANTA INTO AMPLITUDE-PROPORTIONAL ELECTRICAL SIGNALS FOR FURTHER PROCESSING IN A SPECTROMETRIC DEVICE. THE DEWAR VESSEL BUILT INTO THE DETECTOR PROVIDES COOLING OF THE DETECTOR BY LIQUID NITROGEN TO WORKING TEMPERATURE. THE MAIN PARAMETERS: - ENERGY RANGE FROM 50 TO 10000 KEV; - ENERGY RESOLUTION ON 122 KEV 57CO NO MORE THAN 0 85 KEV - ENERGY RESOLUTION ON 1 33 MEV 60CO NOT MORE THAN 1.8 KEV - RELATIVE EFFICIENCY OF 1.33 MEV 60CO NOT LESS THAN 25%. CONDENSATION) 85% - ATMOSPHERIC PRESSURE FROM 86 TO 106 KPA - GAMMA RADIATION POWER NOT MORE THAN 0.2 ?SV / H. DOES NOT BELONG TO THE MILITARY DUAL-USE GOODS. DOES NOT CONTAIN SOURCES OF IONIZING RADIATION. RETURN AFTER WARRANTY REPAIR.
HS-Code
Products
9030100000
1. SCINTILLATION DETECTOR LB6739-01 # 48452-01 / SCINTILLATION DETECTOR LB6739-01 -3 PCS. IS (SCINTILLATION COUNTER) INSTRUMENTS FOR MEASURING IONIZING RADIATION USED TO MEASURE THE LEVEL OF LIQUID STEEL IN THE CRYSTALLIZER AND BASED ON THE USE OF GAMMA RADIATION (IS RADIATION SOURCES) CASE MATERIAL: STAINLESS STEEL 1.4301. CRYSTAL: CSI D = 40/50 OR D = 25/50. OPERATING TEMPERATURE: -20 ... + 50 (-4 ... 122 F) AT> 50 DEGREES. CELSIUS NEEDS WATER COOLING. POWER SUPPLY: 12-24 V 1.2 W. DEGREE OF PROTECTION IP67. FOR OWN PRODUCTION NEEDS.
9030100000
1. SCINTILLATION DETECTOR LB6739-01 # 48452-01 / SCINTILLATION DETECTOR LB6739-01 - 2 PCS. IT IS A (SCINTILLATION COUNTER) DEVICE FOR MEASURING IONIZING RADIATION USED TO MEASURE THE LEVEL OF LIQUID STEEL IN THE MOLD AND BASED ON THE USE OF GAMMA RADIATION (DOES NOT CONTAIN SOURCES OF IONIZING RADIATION). HOUSING MATERIAL: STAINLESS STEEL 1.4301. CRYSTAL: CSI D = 40/50 OR D = 25/50. OPERATING TEMPERATURE: -20 ... + 50 (-4 ... 122 F) AT> 50 DEGREES. CELSIUS NEEDS WATER COOLING. POWER SUPPLY: 12-24 V 1.2 W. DEGREE OF PROTECTION IP67. FOR OWN PRODUCTION NEEDS.
9030100000
1. DEVICES FOR MEASURING IONIZING RADIATION. - MOLD CASTER SENSOR V3.1-BGO AND CABLE - 2PCS. SCINTILLATION DETECTOR MOLD CASTER SENSOR V3.1 COMPLETE WITH BGO CRYSTAL AND CABLE. IS A DEVICE FOR MEASURING IONIZING RADIATION USED TO MEASURE THE LEVEL OF LIQUID STEEL IN THE MOLD AND BASED ON THE USE OF GAMMA RADIATION (DOES NOT CONTAIN SOURCES OF IONIZING RADIATION). PRODUCTION NEEDS.
HS-Code
Products
9022290000
1. EQUIPMENT USING GAMMA RADIATION: - DENSITY ANALYZER LB474 BERTHOLD PIPELINE: DIAM.310.0X18.5 MM - 2PCS. SUPPLIED WITHOUT A SOURCE OF ISOTOPIC RADIATION 137CS 80.0 MKU IN A DISASSEMBLED STATE FOR EASE OF TRANSPORTATION. IT CONSISTS OF: -PRO LB474-02-M # 64575-2PCS (SERIAL NUMBERS: 64575-6625 64575-6627) - CABIN FOR WALL MOUNTING # 47443 (INCLUDING TERMINAL BLOCK # 59477) - 2 PCS - 21TE PANEL FOR UNFILLED SEAT # 37526-2 PCS - DETECTOR LB4700-11-00-80-A1-000 50/50 MM # 56926-002 - 2 PCS (SERIAL NUMBERS: 56926-002-6134 56926-002-66135) - PROTECTIVE CONTAINER LID # 52752 - 2 PCS .- MOUNTING FRAME DIAM.305 ... 520MM # 41828- 2 PCS. DESIGNED EXCLUSIVELY FOR MEASURING THE DENSITY OF PULP AT PJSC POLTAVA GOK DUE TO GAMMA RADIATION. NOT FOR MILITARY USE.
9022290000
1. EQUIPMENT USING GAMMA RADIATION: - COMMERCIAL NAME DENSITY ANALYZER LB474 BERTHOLD PIPELINE: TRELLEX DIAM.341.0X13.0 MM STEEL + RUBBER LINING 5 MM MEASURING RANGE: 1.2 ... 2.2 DENSITY - 3PCS. THE DENSITY ANALYZER LB474 BERTHOLD IS DESIGNED EXCLUSIVELY FOR MEASURING THE DENSITY OF THE PULP AT PJSC POLTAVA GOK DUE TO GAMMA RADIATION SUPPLIED WITHOUT A SOURCE OF ISOTOPIC RADIATION 137CS 80.0 MKU IN A DISASSEMBLED FOR TRANSPORTATION STATE TRELLEX DIAM.341.0X13.0 MM STEEL + RUBBER LINING 5 MM. CONSISTS OF: - PROCESSOR MODULE LB 474-01-M0 # 64576 - 3 PCS. SERIAL NUMBERS: 64576-6240 64576-6242 64576- 6243- CABIN FOR WALL MOUNTING # 47443 (INCLUDING TERMINAL BLOCK # 59477) - 3 PCS.- PANEL 21TE FOR UNFILLED SEAT # 37526 - 3 PCS.- DETECTOR LB4700-11-00-80-A1-000 50/50 MM # 56926 -002 - 3 PCS. SERIAL NUMBERS: 56926-002-6151 56926-002-6152 56926-002-6153- PROTECTIVE CONTAINER LID # 52752 - 3 PCS. - MOUNTING ??? ?
HS-Code
Products
9030900000
1. PARTS AND ACCESSORIES TO DEVICES AND DEVICES FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION. DETECTION UNIT MODEL GEM10P4-70-COAXIAL GAMMA DETECTOR BASED ON PURE GERMANIUM (OCHG) ART. GEM10P4-70 - 1 PIECE. CFG-PS4-MOBIUS-B-DET -1 PIECE. DIGITAL MULTICHANNEL ANALYZER SPECTROMETER ART. DSPEC-JR-2.0 - 1 PC. INTERFACE BLOCK ART. DIM-POSGE - 1 PIECE (PARTS AND ACCESSORIES FOR SPECTROMETRIC SYSTEMS STPK. USED FOR WORK RELATED TO ENVIRONMENTAL PROTECTION) MANUFACTURER: AMETEK ADVANCED MEASUREMENT TECHNOLOGY BRAND: ORTEC COUNTRY OF MANUFACTURE: US
9030900000
1. PARTS AND ACCESSORIES TO DEVICES AND DEVICES FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION. DETECTION UNIT MODEL GEM10P4-70-COAXIAL GAMMA DETECTOR BASED ON PURE GERMANIUM (OCHG) ART. GEM10P4-70 - 1 PIECE. CFG-PS4-MOBIUS-B-DET -1 PIECE (PARTS AND ACCESSORIES FOR SPECTROMETRIC COMPLEXES STPK. USED FOR WORK RELATED TO ENVIRONMENTAL PROTECTION) MANUFACTURER: AMETEK ADVANCED MEASUREMENT TECHNOLOGY BRAND: ORTEC COUNTRY OF MANUFACTURE: US
HS-Code
Products
9030908500
1. PARTS AND ACCESSORIES FOR INSTRUMENTS AND APPARATUS FOR DETECTING OR MEASURING IONIZING RADIATION. DETECTION UNIT MODEL GEM10P4-70 -COAXIAL GAMMA DETECTOR BASED ON ULTRAPURE GERMANIUM (OCHG) -1PC .; COOLING SYSTEMOCHG DETECTOR MOBIUS-MOBIUS-CFOB-PSG -DET) -1PC; DIGITAL MULTICHANNEL ANALYZER-SPECTROMETER DSPEC-JR-2.0 -1PC; INTERFACE UNIT DIM-POSGE -1PC; (COMPONENTS OF SPECTROMETRIC COMPLEXESSTPK-01; USED FOR WORK RELATED TO ENVIRONMENTAL PROTECTION)
9030908500
1. PARTS AND ACCESSORIES TO DEVICES AND DEVICES FOR DETECTION OR MEASUREMENT OF IONIZING RADIATION. DETECTION UNIT MODEL GEM20P4-70 COAXIAL GAMMA DETECTOR BASED ON ULTRAPURE GERMANIUM ART. GEM10P4-70 -1 PIECE; DEWAR VESSEL 30LDWR30 PIECE; -PV4 ART.CFG-PS4-MOBIUS-B-DET -1PC; DIGITAL MULTICHANNEL ANALYZER-SPECTROMETER ITEM DSPEC-JR -2.0 -1PC; INTERFACE MODULE ITEM DIM-POSGE -1PC; (COMPONENTS OF SPECTROMETRIC COMPLEXES; USED FOR WORK RELATED TO ENVIRONMENTAL PROTECTION)
We have given over thousands of our clients a reason to be happy with the business results they have gained by using TTV.